Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add filters








Year range
1.
Chinese Journal of Experimental Traditional Medical Formulae ; (24): 165-170, 2019.
Article in Chinese | WPRIM | ID: wpr-801780

ABSTRACT

Objective: To study the correlation between the color of Indigo Naturalis (powder and it's extracting solution) and effective components (indigo and indirubin) content. Method: The contents of indigo and indirubin in 27 batches of Indigo Naturalis were determined by HPLC,and the chromaticity values L*,a* and b* of powder and extracting solution were determined by color colorimeter. SPSS 20.0 software was used to analyze the correlation and multiple linear regression between the content of active components and the chromaticity values of Indigo Naturalis. Result: By visual observing the appearance of the powder,we find that,as the powder color deepened,the brightness values (L*) of the powder and extract were decreased,while the red-green value (a*) were increased. The correlation analysis showed that the contents of indigo were negatively correlated with the brightness value (L*) of the powder(Pa*)(PL*) of powder and extract (Pa*) (PConclusion: The darker the powder color of Indigo Naturalis,the higher the content of indigo and indirubin. The L* and a* values of indigo powder were more correlated with indigo and indirubin content than with the extracting solution. The color of powder was significantly correlated with the content of indigo and indirubin,which provided reference for rapid identification of Indigo Naturalis. The method of measuring the color of Indigo Naturalis by color colorimeter is stable,scientific and reliable.

2.
Chinese Herbal Medicines ; (4): 388-395, 2018.
Article in Chinese | WPRIM | ID: wpr-842105

ABSTRACT

Objective: Crude Leonuri Fructus (CLF), the fruits of the Leonurus japonicus Houtt, and processed Leonuri Fructus (PLF) by stir-baking as the important Chinese herbal medicines, have been used in China and other Asian countries for thousands of years. The objective of this research is to reveal the difference between CLF and PLF. Methods: The sensory technologies of the colorimetry, sensitive and validated HPLC-ELSD and GC combined with flame ionization detector (GC-FID) were employed to discriminate CLF and its processed product PLF. The color parameters of the samples were determined by colorimetric instrument CR-410. Moreover, the content of stachydrine and six fatty acids were determined by HPLC and GC. Subsequently, analysis of variance (ANOVA), principal components analysis (PCA), hierarchical cluster analysis (HCA), and Kendall's correlation test were performed for data analysis. Results: The CLF and PLF were divided into two categories by PCA and HCA in terms of their component content and color. The results distinctly demonstrated significant changes in color and the content of indicative components between CLF and PLF. Conclusion: The study revealed that HPLC, GC, and colorimetric method in combination with chemometric method could be used as comprehensive quality evaluation for CLF and PLF.

3.
Braz. dent. j ; 28(5): 624-631, Sept.-Oct. 2017. tab, graf
Article in English | LILACS | ID: biblio-888690

ABSTRACT

Abstract The aim of this study was to evaluate the degree of conversion, color stability, chemical composition, and bond strength of a light-cured resin cement contaminated with three different hemostatic solutions. Specimens were prepared for the control (uncontaminated resin cement) and experimental groups (resin cement contaminated with one of the hemostatic solutions) according to the tests. For degree of conversion, DC (n = 5) and color analyses (n = 10), specimens (3 mm in diameter and 2 mm thick) were evaluated by Fourier transform infrared spectroscopy (FTIR) and CIELAB spectrophotometry (L*, a*, b*), respectively. For elemental chemical analysis (n = 1), specimens (2 mm thick and 6 mm in diameter) were evaluated by x-ray energy-dispersive spectroscopy (EDS). The bond strengths of the groups were assessed by the microshear test (n = 20) in a leucite-reinforced glass ceramic substrate, followed by failure mode analysis by scanning electron microscopy (SEM). The mean values, except for the elemental chemical evaluation and failure mode, were evaluated by ANOVA and Tukey's HSD test. The color stability was influenced by storage time (p<0.001) and interaction between contamination and storage time (p<0.001). Hemostop and Viscostat Clear contamination did not affect the DC, however Viscostat increased the DC. Bond strength of the resin cement to ceramic was negatively affected by the contaminants (p<0.001). Contamination by hemostatic agents affected the bond strength, degree of conversion, and color stability of the light-cured resin cement tested.


Resumo O objetivo desse estudo foi avaliar o grau de conversão, estabilidade de cor, composição química e resistência de união de um cimento resinoso fotoativado contaminado com três soluções hemostáticas diferentes. Foram preparadas amostras para o grupo controle (cimento não contaminado) e grupos experimentais (cimento contaminado com uma das soluções hemostáticas) de acordo com os testes. Para o grau de conversão e análise de cor (n=10), as amostras (3 mm de diâmetro e 2 mm de espessura) foram avaliadas por espectroscopia de infravermelho com transformação de Fourier (FTIR) e espectrofotometria CIELAB (L*, A*, B*), respectivamente. Para a análise química elementar (n=1), os espécimes (2 mm de espessura e 6 mm de diâmetro) foram avaliados por espectroscopia de energia dispersiva de raios-x (EDS). As resistências de união dos grupos foram avaliadas pelo ensaio de microcisalhamento (n=20) em um substrato cerâmico de vidro reforçado com leucita, seguida da análise de modo de falha por microscopia eletrônica de varredura (MEV). Os valores médios, com exceção da avaliação química e do modo de falha, foram avaliados por ANOVA e pelo teste de Tukey. A estabilidade de cor foi influenciada pelo tempo de armazenagem (p<0,001) e interação entre a contaminação e o tempo (p<0,001). A contaminação pelo Hemostop e Viscostat Clear não influenciaram no GC, porém a contaminação com Viscostat aumentou o GC. A resistência de união do cimento a cerâmica foi negativamente afetada pelos contaminantes (p<0,001). A contaminação por agentes hemostáticos afetou a resistência de união, o grau de conversão e a estabilidade de cor do cimento resinoso fotoativado testado.


Subject(s)
Hemostatics , Resin Cements/chemistry , Color , Microscopy, Electron, Scanning , Solutions , Spectrum Analysis , Surface Properties
4.
Journal of the Korean Society of Plastic and Reconstructive Surgeons ; : 365-371, 2009.
Article in Korean | WPRIM | ID: wpr-62180

ABSTRACT

PURPOSE: Good color match is a key element in facial reconstruction for good aesthetic result. To correct the wide facial soft tissue defect were usually used the tissue expanded cheek flap, deltopectoral flap or radial forearm free flap. This study is aimed to analyse the color difference after flap surgery by using chromameter. METHODS: From August 1995 to December 2006, 30 patients who underwent flap operations were chosen randomly and evaluated color differences between flap site and adjacent skin. Reconstructive procedures included tissue expanded cheek flap(n=10), deltopectoral flap(n= 10), and radial forearm free flap(n=10). The measured sites were flap center within a radius of 1cm and four points of adjacent skin along the flap margin. The colors were quantified in a three dimensional coordinate system composed of L* (brightness), a*(redness), b*(yellowness). RESULTS: There were no significant color differences between the pedicled flaps(tissue expanded cheek flap and deltopectoral flap) and adjacent skin area. On the other hand, color values of the radial forearm free flap were statistically different from those of adjacent skin area. Total color difference(delta E) of tissue expanded cheek flap and deltopectoral flap were 7.45+/-5.78 versus 9.41+/-7.09, and that of radial forearm free flap was 11.74+/-3.85. It suggests that pedicled flaps have a potential of better color match than radial forearm free flap. CONCLUSION: Thus, better esthetic results and satisfaction is more likely to be expected in pedicled flaps as long as it could be applied comparing radial forearm free flap.


Subject(s)
Humans , Cheek , Forearm , Free Tissue Flaps , Hand , Radius , Skin , Surgical Flaps
5.
Journal of the Korean Society of Plastic and Reconstructive Surgeons ; : 35-40, 2008.
Article | WPRIM | ID: wpr-113664

ABSTRACT

PURPOSE: For facial reconstruction, skin color match is crucial to achieve great aesthetic result. Forehead flap and full thickness skin graft have been used for many years to reconstruct facial defect. Their results are aesthetically valuable with remarkable resemblance and harmony of the skin color between donor and recipient sites. The purpose of this study is to evaluate and compare the aesthetic outcome of the two methods as the analysis of skin color match. METHODS: From January 1995 to December 2005, ten forehead flaps and ten full thickness skin grafts were performed. The reconstructed areas of forehead flaps were five noses and five eyelids. Recipient sites of full thickness skin grafts were seven eyelids, two noses and one forehead. In order to obtain the objective validity, the skin color of flap(or graft) and the recipient sites were measured by chromameter. The skin colors were quantified according to a three-dimensional coordinate system used in chromameter, L*(brightness), a*(redness), and b*(yellowness). RESULTS: There was no significant color difference between forehead flap site and adjacent skin in all color values. On the other hand, the L* and b* values of graft sites were significantly lower than those of the adjacent skins. The a* values of graft sites were higher than those of the adjacent skins. CONCLUSION: This study reveals that skin color match of forehead flap is greater than that of full thickness skin graft. As forehead flap has adequate volume and great color match, it can be useful to reconstruct deep facial defect such as nasal defect. On the other hand, full thickness skin graft can be used for superficial defect like partial eyelid defect.


Subject(s)
Humans , Eyelids , Forehead , Hand , Nose , Skin , Tissue Donors , Transplants
6.
Journal of Korean Academy of Conservative Dentistry ; : 352-368, 2008.
Article in Korean | WPRIM | ID: wpr-89611

ABSTRACT

This study was done to evaluate the reliability of the digital color analysis system (ShadeScan, CYNOVAD, Montreal, Canada) for dentistry. Sixteen tooth models were made by injecting the A2 shade chemical cured resin for temporary crown into the impression acquired from 16 adults. Surfaces of the model teeth were polished with resin polishing cloth. The window of the ShadeScan handpiece was placed on the labial surface of tooth and tooth images were captured, and each tooth shade was analyzed with the ShadeScan software. Captured images were selected in groups, and compared one another. Two models were selected to evaluate repeatability of ShadeScan, and shade analysis was performed 10 times for each tooth. And, to ascertain the color difference of same shade code analyzed by ShadeScan, CIE L*a*b*values of shade guide of Gradia Direct (GC, Tokyo, Japan) were measured on the white and black background using the Spectrolino (GretagMacbeth, USA), and Shade map of each shade guide was captured using the ShadeScan. There were no teeth that were analyzed as A2 shade and unique shade. And shade mapping analyses of the same tooth revealed similar shade and distribution except incisal third. Color difference (DeltaE*) among the Shade map which analyzed as same shade by ShadeScan were above 3. Within the limits of this study, digital color analysis instrument for dentistry has relatively high repeatability, but has controversial in accuracy.


Subject(s)
Adult , Humans , Composite Resins , Crowns , Dentistry , Tokyo , Tooth
7.
Journal of Practical Stomatology ; (6)2000.
Article in Chinese | WPRIM | ID: wpr-670558

ABSTRACT

Objective: To study the color in ShoFu colormeter plate. Methods: The values of color degree of the cervical, body and incisal end of various teeth in the ShoFu colormeter plate were measured by digital camera and analyzed by computer using CIE1976L*a*b* system and JISZ8722 standard. Results: In ShoFu plate the brightness in the cervical, body and incisal end of various teeth changed following a certain rule, the brightness in group R and VR were higher than that in group A. While the values of color degree in other groups changed without any rule. Conclusion: The digital camera and computer may be used in dental color study.

SELECTION OF CITATIONS
SEARCH DETAIL